Operating procedures for the hot-water tank of a double-layer water-bath sterilization pot
Release Date:
2021-12-24
Double‑layer water bath sterilization kettles are widely used in our daily lives, yet many people are not fully familiar with the proper operating sequence. Let’s take a look at the step‑by‑step procedure for using a double‑layer water bath sterilization kettle.
Double-layer water bath sterilization pot It is widely used in our daily lives, yet many people are not fully familiar with the operating sequence of a double‑layer water bath sterilizer. Let’s take a look at the working steps of this equipment!
1. Adding water to the pot: Place the sterilization pot into the lower vessel, lock the door and wait for the alarm to sound, then press the green “Sterilization” button. The system will automatically check whether the pressure in the upper water tank has reached the preset level; this is referred to as the “upper tank’s make-up valve.”
2. Temperature rise in the double‑layer water‑bath sterilization pot: With the communication valve, circulating inlet valve, circulating outlet valve, circulation pump, and steam valve all open, the pressure inside the pot automatically maintains the set pressure; once the set sterilization temperature is reached, the system enters the holding phase.
3. Temperature‑controlled sterilization: Sterilization begins once the set sterilization temperature is reached; during this phase, temperature and pressure are carefully maintained, and upon completion of the prescribed holding time, a hot‑water recovery step is carried out.

4. Hot-water recovery procedure: Open the connecting valve, the hot-water recovery valve, the circulating outlet valve, and the circulation pump; pressure in the boiler is automatically regulated. When the water level in the boiler reaches the low‑level threshold or the upper water tank reaches the high‑level threshold, the transfer to the next operation step is completed.
5. Cooling and Water Filling: First, open the feedwater pump, the connecting valve, and the water‑supply bypass valve. Once the boiler temperature drops to the set opening temperature of the main water‑supply valve, the main valve opens, accelerating the water‑filling process. During this phase, pressure is self‑regulated, and when the water level reaches the lower limit, the system transitions to the next operating cycle.
6. Circulating Cooling: The circulation pump starts, the circulating outlet valve and the circulating inlet valve open, with pressure automatically regulated. The system then initiates the cooling cycle; once the preset cooling duration is reached, it proceeds to the next operational step.
7. Drainage in the boiler: Open the drain valve and the circulation pump, use the pump to discharge the cooled circulating water, and continue draining until the preset low-water level is reached, then proceed to the venting step.
8. Venting: Open the vent valve to release any residual air from the pot until the pressure inside the pot reaches zero.
9. End of operation: Reset the system, sound an audible alarm, and notify the operator that product sterilization has been completed.
The double‑layer water‑bath sterilizer features short sterilization times and rapid temperature rise. By circulating hot water between two tanks, it can heat the hot‑water tank to the required sterilization temperature before transferring the product to the sterilization chamber, thereby reducing the time needed to bring the medium up to temperature. The working medium can be recovered and reused, enabling the high‑temperature sterilizer to save energy, time, and labor, thus lowering production costs. This double‑layer water‑bath sterilizer employs reliable technology and computer‑controlled components, utilizing a recirculating hot‑water system within the vessel to perform immersion‑type high‑temperature sterilization. During operation, the unit uses computer‑assisted automation to precisely regulate internal temperature and pressure, sterilization time, steam admission and exhaust, as well as water inflow and outflow, maintaining an internal temperature accuracy of approximately ±0.3°C. This ensures that the color, flavor, and nutritional content of the finished product remain unchanged.
The above is what has been introduced. Double-layer water bath sterilization pot The work steps—please feel free to contact us anytime if you’d like to learn more!